C H A N G E L O G
Please note: Only use the firmware file in connection with the current software-version
of the CCUx!
Device: HmIP-STH - Homematic IP Temperature and Humidity Sensor - indoor
Company: eQ-3, Maiburger Str. 29, 26789 Leer, Germany
Version 3.0.2 - 2024-04-08
** Bugfix
- The "Heating Controller Mode" frame was sent several times.
The "Heating Controller Mode" telegram was sent cyclically to each channel of the
FAL. It is sufficient if the telegram is sent to the FAL only once.
- Boosttime was set in Party-Status-Info-Frame even if boost was not active.
- Boot flag is reset prematurely.
If a time info request is sent after a restart, the boot flag must not be missing
in the regular status frame. If no response is sent from the access point to the
time info request after a restart, the boot flag must not be reset in the status
until the status frame has been acknowledged.
- The device send no DEC telegram to link partners if a new link partner was
previously added or removed.
- Instead of a conditional switch command the device should send a level command to
linked switch actuators. This allows the actuator to be deactivated directly by
the wall thermostat
- Emergency shutdown at 30°C during cooling.
Cooling is also active when the set temperature is greater than 30.0°C
- Hysteresis for 2-point control with switching actuator does not work as specified.
The hysteresis was not evaluated correctly for the humidity. The resolution
should be 1%. However, it actually had a resolution of 2%.
** Improvement
- The automatic switchover from manu-mode to auto-mode after a restart following
receipt of the first time-info telegram should be deactivated.
- The "Heating Controller Mode" frame was sent several times.
The "Heating Controller Mode" telegram was sent cyclically to each channel of the
FAL. It is sufficient if the telegram is sent to the FAL only once.
- Instead of a conditional switch command the device should send a level command to
linked switch actuators. This allows the actuator to be deactivated directly by the
wall thermostat.
- The cooling profile factory setting is set to 28°C.
** New Feature
* Implementation of the "Heating controller 2 bit field" parameter in list 1 for
channel 5
The parameter values COOLING_ENABLE and HEATING_ENABLE were added for channel 5
(Actuator link partner). This makes it possible to deactivate cooling or heating
in the respective mode.
Version 2.8.010 - 2022-10-10
** Bugfix
- After reinclusion, partly cyclic data telegrams for eTRV, actuator and FAL are not
sent.
Version 2.8.002 - 2021-12-08
** Bugfix
- Device does not respond to ALL_TRIPLE_BURST_LISTENING_DEVICES.
A generally valid message to the address ALL_TRIPLE_BURST_LISTENING_DEVICES is
supported now.
- DRIx window contacts of a room cannot form the necessary AND connection.
If a window contact with several channels is linked as partner, window-closed was
already detected if only one channel of the window contact reported window-closed.
** New Feature
- Switchover for use either as thermostat or as hygrometer (2-point control) with
effect on the actor channel and/or internal switching actuator.
Via the parameter setting it is now possible to switch the actuator channel 5
depending on the humidity.
** Improvement
- Whenever connection to link partner FAL is checked, the led is blinking.
If the wall thermostat is linked to a FAL or FALMOT, the link connection is
checked every 50 minutes as standard. This results in a flashing LED on the
thermostat. Especially if the connection is made via a router, this flashing could
take longer. This should not be the case as it will cause confusion for customers.
The LED should only be triggered when the customer makes manual changes.
- The time information telegram does not contain a note about the summer / winter
time change.
So it was possible that a time request to the access point in the period where the
changeover from summer to winter time takes place could lead to a double
changeover.
- Automatic switching between heating and cooling at the two-point control for
actuator channel 5.
Up to now, the parameter "Art der Zweipunktregelung" was used to specify whether
the two-point control for the actuator channel 5 should heat or cool. This
parameter has now been extended by the value heating and cooling. If this value is
now selected, the two-point control is automatically changed to heating or
cooling.
- Smart RX FAL cyclic packet reduction
To reduce the radio load, a check is made before each cyclic data telegram is sent
to the FAL or FALMOT to determine whether it actually has to be sent. If there has
been no change in the mode, the actual temperature, the humidity and the set
temperature, the packet does not have to be sent every cycle.
Version 2.6.000 - 2019-09-04
** New Feature
- Improvement for data communication.
If possible the device send multicasts only to PARTNER_ALL_WIRED_DEVICES instead
of to PARTNER_ALL_DEVICES.
** Improvement
- Immediate evaluation of temperature change for the two-point-control.
Temperature changes triggered by the central unit or a window contact, are
forwarded directly to the switching actuators for the two-point-control.
Version 2.4.008 - 2019-03-07
** Bugfix
- Logic "Window open temperature" corrected in cooling mode
In cooling mode, it is not advisable to change to the window open temperature, as
a result, more cooling would have to be used.
- Error when changing from winter to summer time.
On the day of the time change, the time is increased by one hour every full hour
after 2 o'clock.
** Modification
In "Duration" replace the unit "Days" by "10ms".
Revision of the current duration, becaues a 16 bit value are not needed as unit
"Days" anyway.
** Improvement
Adjustment of the LCD start display
In the future only the application version major minor will be shown in the LCD
start display. All further information can be found in the app or the ccu.
Version 2.2.002 - 2017-09-29
** Bugfix
- Correction when trying changing from manu to auto mode if the time is not known.
In manu mode boost is not activated by a long button press if the time is not
known.
- Correction in Paging-Module HMOS-Library
Catched erros which could occure after an OTAU update to a newer paging module.
- Correction for the Optimum Start Stop function
After activating the optimum start stop function it is now executed correctly.
- Missing port initialization for the HmIP-STHD
The setpoint temperature can be changed by static charging.
** New Feature
- Parameter extension for installer solution.
With the help of the new parameter "DISABLE_MSG_TO_AC" all transmissions to the
central address are suppressed. Also to the status receiver address if this is the
same as the central address.
Version 2.0.000 - 2017-07-20
** Bugfix
- Correction for set point temperature update after weekprogram configuration.
If window open is detected (extern/intern) and during this time a new week program
is transmitted to the device, the device updated the set point temperature after
window close by using the new week program set point temperature.
- Extension for the Quick Veto Function.
If the quick veto function is active, the remaining time is transferred in the
status telegram.
- Behavior after aborting the factory reset.
If the factory reset is aborted or not executed until the end, the device performs
a reboot after the termination or after the timeout.
- Correction when trying changing from manu mode to auto mode if the time is not
known.
In manu mode boost is not activated by a long button press if the time is not
known.
- Abort of Quick Veto by "Duration = 0".
If Quick Veto is active, Quick Veto can be aborted by the radio command
"Duration = 0". The device answers the radio telegram with an "Ack".
Version 1.8.004 - 2017-03-28
** Bugfix
- New data packages will not be sent until the current data transmission has
finished.
- After bug fix no more cyclic messages were sent after a manual operation
- Improved handling at quick-veto
Function is communicated to the link partner via a DEC-Command with
"Duration-Time".
- Bug fixing in temperature week program
If one daily temperature profiles consist of only one switch time point, the
switch time point is skipped by midnight of the next day.
- Bug fixing optical system LED flashing
The corresponding system LED flashing sequence has not been reproduced correctly,
if the factory set was not be executable, because of the the LOCAL_RESET_DISABLE
bit is set.
- The hour was not taken into account during the transition from summer to winter
time or from winter to summer time, so the conversion took place at 00:00.
** New Feature
- Implementation of Quick-Veto-Function
Version 1.6.000 - 2016-08-16
** First release
--- END OF FILE ---