C H A N G E L O G
Please note: Only use the firmware file in connection with the current software-version
of the CCUx!
Device: HmIP-BWTH24 - Homematic IP Wall Thermostat with switching output
Company: eQ-3, Maiburger Str. 29, 26789 Leer, Germany
Version 3.0.4 - 2024-12-02
** Bugfix
- Symbol display for heating / cooling is missing if an actuator link exists.
With the new FW version it is now possible to operate the two-point control
depending on the operating mode (heating / cooling). Here, the symbol should also
be shown on the display accordingly.
- The Encoder-Button response without backlight "Off", only worked every second time.
- The "Heating Controller Mode" frame was sent several times.
The "Heating Controller Mode" telegram was sent cyclically to each channel of the
FAL. It is sufficient if the telegram is sent to the FAL only once.
- Boosttime was set in Party-Status-Info-Frame even if boost was not active.
- Boot flag is reset prematurely.
If a time info request is sent after a restart, the boot flag must not be missing
in the regular status frame. If no response is sent from the access point to the
time info request after a restart, the boot flag must not be reset in the status
until the status frame has been acknowledged.
- The device send no DEC telegram to link partners if a new link partner was
previously added or removed.
- Instead of a conditional switch command the device should send a level command to
linked switch actuators. This allows the actuator to be deactivated directly by
the wall thermostat
- Emergency shutdown at 30°C during cooling.
Cooling is also active when the set temperature is greater than 30.0°C
- Hysteresis for 2-point control with switching actuator does not work as specified.
The hysteresis was not evaluated correctly for the humidity. The resolution
should be 1%. However, it actually had a resolution of 2%.
- In stand-alone operation, the sense of NO and NC was swapped.
- In FW 2.8.10 the device sporadically sends inexplicably frequent status frames to
the AP/CCU
- The switching state is not restored after a power failure
After a power failure, the switching output was not reactivated if it was
previously switched. However, active was still displayed in the status frame.
- Continuous flashing if present in central program
If the central unit was linked as a link partner, the orange transmission
flashing was not ended by the confirmation ACK but only after the timeout. After
the timeout, the LED briefly lit up red.
- The device no longer works if the parameter PUMP_SWITCHING_INTERVAL in channel 14
are set to zero (not active).
- After deleting the internal link between channel 8 and channel 10, the level state
is not reset to 0. As a result, the temperature compensation is no longer carried
out correctly and the actual temperature is displayed with a value that is too low.
** Improvement
- The automatic switchover from manu-mode to auto-mode after a restart following
receipt of the first time-info telegram should be deactivated.
- The "Heating Controller Mode" frame was sent several times.
The "Heating Controller Mode" telegram was sent cyclically to each channel of the
FAL. It is sufficient if the telegram is sent to the FAL only once.
- Instead of a conditional switch command the device should send a level command to
linked switch actuators. This allows the actuator to be deactivated directly by the
wall thermostat.
- The cooling profile factory setting is set to 28°C.
- Reduction of status messages, when the relay status changes, not the complete
status information is sent.
** New Feature
- Implementation of the "Heating controller 2 bit field" parameter in list 1 for
channel 5
The parameter values COOLING_ENABLE and HEATING_ENABLE were added for channel 5
(Actuator link partner). This makes it possible to deactivate cooling or heating
in the respective mode.
Version 2.8.010 - 2022-10-10
** Bugfix
- After reinclusion, partly cyclic data telegrams for eTRV, actuator and FAL are not
sent.
Version 2.8.008 - 2022-09-06
** Bugfix
- Device does not respond to ALL_TRIPLE_BURST_LISTENING_DEVICES.
A generally valid message to the address ALL_TRIPLE_BURST_LISTENING_DEVICES is
supported now.
- DRIx window contacts of a room cannot form the necessary AND connection.
If a window contact with several channels is linked as partner, window-closed was
already detected if only one channel of the window contact reported window-closed.
- Display error when switching between temperature and humidity.
Every 60 seconds when updating the display, humidity is very briefly displayed,
but then immediately jumps back to the actual temperature.
- Whenever connection to link partner FAL/MIOB/WHS2 is checked, the led is blinking.
If the wall thermostat is linked to a FAL/MIOB/WHS2, the link connection is
checked every 50 minutes as standard. This results in a flashing LED on the
thermostat. Especially if the connection is made via a router, this flashing could
take longer. This should not be the case as it will cause confusion for customers.
The LED should only be triggered when the customer makes manual changes.
** New Feature
- Extension by boiler and pump channel for direct control via Multi IO Box and Switch
Actuator for heatings system.
The expansion allows the heating system to be controlled even if the central unit
fails. The direct links ensure reliable operation even in offline mode.
- Switchover for use either as thermostat or as hygrometer (2-point control) with
effect on the actor channel.
Via the parameter setting it is now possible to switch the actuator channel 5
depending on the humidity.
** Improvement
- Parameters for switching between PWM and 2-point-control for floor heating control.
It is now possible to select via a parameter whether the control of the underfloor
heating is carried out using the previously used PWM control or whether the
control is realised with a 2-point control.
- Whenever connection to link partner FAL is checked, the led is blinking.
If the wall thermostat is linked to a FAL or FALMOT, the link connection is
checked every 50 minutes as standard. This results in a flashing LED on the
thermostat. Especially if the connection is made via a router, this flashing could
take longer. This should not be the case as it will cause confusion for customers.
The LED should only be triggered when the customer makes manual changes.
- The time information telegram does not contain a note about the summer / winter
time change.
So it was possible that a time request to the access point in the period where the
changeover from summer to winter time takes place could lead to a double
changeover.
- Automatic switching between heating and cooling at the two-point control for
actuator channel 5.
Up to now, the parameter "Art der Zweipunktregelung" was used to specify whether
the two-point control for the actuator channel 5 should heat or cool. This
parameter has now been extended by the value heating and cooling. If this value is
now selected, the two-point control is automatically changed to heating or
cooling.
- Smart RX FAL cyclic packet reduction
To reduce the radio load, a check is made before each cyclic data telegram is sent
to the FAL or FALMOT to determine whether it actually has to be sent. If there has
been no change in the mode, the actual temperature, the humidity and the set
temperature, the packet does not have to be sent every cycle.
Version 2.6.000 - 2019-09-04
** New Feature
- Improvement for data communication.
If possible the device send multicasts only to PARTNER_ALL_WIRED_DEVICES instead
of to PARTNER_ALL_DEVICES.
** Improvement
- Immediate evaluation of temperature change for the two-point-control.
Temperature changes triggered by the central unit or a window contact, are
forwarded directly to the switching actuators for the two-point-control.
Version 2.4.008 - 2019-03-07
** Modification
In "Duration" replace the unit "Days" by "10ms".
Revision of the current duration, becaues a 16 bit value are not needed as unit
"Days" anyway.
** Improvement
Adjustment of the LCD start display
In the future only the application version major minor will be shown in the LCD
start display. All further information can be found in the app or the ccu.
Version 1.2.004 - 2017-11-23
** Bugfix
- Logic "Window open temperature" corrected in cooling mode
In cooling mode, it is not advisable to change to the window open temperature, as
a result, more cooling would have to be used.
- Correction in Paging-Module HMOS-Library
Catched erros which could occure after an OTAU update to a newer paging module.
- Correction for the Optimum Start Stop function
After activating the optimum start stop function it is now executed correctly.
- Antenna symbol synchronization in the display.
If the date and time can be requested by the access point, this is a sign that the
radio communication is in order. The flashing of the antenna symbol should then be
canceled.
- Correction for set point temperature update after weekprogram configuration.
If window open is detected (extern/intern) and during this time a new week program
is transmitted to the device, the device updated the set point temperature after
window close by using the new week program set point temperature.
- Correction when changing from auto mode to manu mode.
When changing from auto mode to manu mode and boost is active, boost is abort.
- Function modification after removing internal link between channel 8 and channel 10.
When removing the internal link between channel 8 and channel 10 by the access
point, the relay should be deactivated.
- Behavior after aborting the factory reset.
If the factory reset is aborted or not executed until the end, the device performs
a reboot after the termination or after the timeout.
- Abort of Quick Veto by "Duration = 0".
If Quick Veto is active, Quick Veto can be aborted by the radio command
"Duration = 0". The device answers the radio telegram with an "Ack".
- Error when changing from winter to summer time.
On the day of the time change, the time is increased by one hour every full hour
after 2 o'clock.
** New Feature
- Parameter extension for installer solution.
With the help of the new parameter "DISABLE_MSG_TO_AC" all transmissions to the
central address are suppressed. Also to the status receiver address if this is the
same as the central address.
** Modification
- Function modification of Optimum-Start-Stop
Change to Optimum Start, means that the comfort temperature should be reached at
the desired point in time, the lowering temperature not.
- Function modification during two-point control.
During the two-point control (startup sequence), the device do observe the
parameter values "COOLING_DISABLE" and "HEATING_DISABLE".
** Improvement
- Improvement for the display.
When changing the temperature offset from the App the LCD display should be updated
directly.
- Expansion for inclusion condition.
If parameter changes have been made to the device before the inclusion, the device
can only be included if a factory reset has been performed on the device before.
- Extension for the Quick Veto Function.
If the quick veto function is active, the remaining time is transferred in the
status telegram.
Version 1.0.011 - 2017-05-12
** First release