C H A N G E L O G
Please note: Only use the firmware file in connection with the current software-version of the CCUx!
Device: HmIPW-FALMOT-C12 - Homematic IP Floor Heating Actuator â 12 channels, motorised
Company: eQ-3, Maiburger Str. 29, 26789 Leer, Germany
Version 1.6.2 - 2024-06-11
** Bugfix
- The device opened the valve in heating mode when the actual temperature is
permanently higher than 32 degrees.
- DST in TimeInfoResponse is not observed, i.e. a time transfer during the
changeover to winter time may temporarily result in an incorrect time.
- Communication test with wall thermostat does not work as expected.
When the test is started, the valve is opened completely. However, if the valve is
already fully open, nothing happens except for the green confirmation flash on the
wall thermostat. The function has been changed as follows: If the valve position
is < 50, 100% is approached, otherwise 0%.
- Bar graph display during adaptation drive does not meet expectations. If the valves
have moved to the end position and the adpation run has not yet been started, all
bars of the valves should be displayed to indicate that they are fully open.
- Pairing from FALMOT-C12 to FALMOT-C12 was acknowledged by red LED
** Improvement
- Valve adaptation was carried out more frequently than necessary during operation.
- Decalcification as the cause of heat pump malfunction
Due to the weekly adaptation run, all valves were closed for a short period of
time, which meant that no more heat was taken and some heat pumps ran into an
error.
Version 1.4.010 - 2023-09-29
** Improvement
- optimization of the valve control
Version 1.4.008 - 2022-09-27
** Modification
Version 1.4.006 - 2021-02-09
** Bugfix
- FALMOT reports disconnection to WTH if "Window open" is reported by WTH for longer
than 3 hours.
As soon as window open was signaled by the WTH, the cyclic telegram set/actual
temperature from the WTH was no longer processed by the device, i.e. set and
actual temperature were not updated until window close.
- When the time request changes to the WTH partner, it does not change back to the
Access Point
If the Access Point is not reachable, the time request is sent to a known WTH. The
time request was then sent permanently to this partner. This led to increased data
communication if routers in the field.
Version 1.4.002 - 2020-11-30
First Release.
--- END OF FILE ---