C H A N G E L O G
Please note: Only use the firmware file in connection with the current software-version of the CCUx!
Device: HmIP-eTRV-C-2 - Homematic IP Radiator Thermostat - Compact
Company: Q-3, Maiburger Str. 29, 26789 Leer, Germany
Version 1.4.014 - 2022-01-28
- Bugfix
- The time information telegram does not contain a note about the summer / winter
time change.
So it was possible that a time request to the access point in the period where the
changeover from summer to winter time takes place could lead to a double
changeover.
- The device no longer heats correctly after a link to the WTH has been created.
If the link between eTRV and WTH was deleted and then a new link was created, the
devices only synchronized again after a restart (battery change) at the eTRV.
- Correction for MANU set point temperature update after window open.
If window open is detected (extern/intern) and during this time the device get the
command "Eco-Mode", the device updated the set point temperature after window
close and "Eco-Mode" off to the old set point temperature.
- If the adaptation drive is faulty, it will not be repeated automatically.
If the adaptation drive fails, it is first repeated automatically before being
aborted with the corresponding error message
- Stabilization of the adaptation drive.
The adaptation drive failed by some valves, this was corrected.
Version 1.4.006 - 2020-10-20
First Release.
--- END OF FILE ---