C H A N G E L O G
Please note: Only use the firmware file in connection with the current software-version of the CCUx!
Device: HmIP-WHS2 - Homematic IP Switch Actuator for heating systems â 2 channels
Company: eQ-3, Maiburger Str. 29, 26789 Leer, Germany
Version 2.0.010 - 2022-05-23
** Bugfix
- Status info cannot request from virtuel channels
- Sorting of status info container wrong
Version 2.0.008 - 2022-05-10
** Improvement
Version 2.0.006 - 2022-04-27
** Bugfix
- Due to the default settings of the link parameters, a conditional switch command is not handled according to specification
Version 2.0.004 - 2022-03-31
** Bugfix
- Weekprogram-Status(-with Ack) is not triggered in case of Mode-Change
- MIOB "Normally Closed"-Input: Cooling is not activated
Version 2.0.000 - 2022-02-07
** Bugfix
- Direct link CO input to FALx deactivates internal channel A
- If the switch-on and switch-off times in the Easy Profile are set to "Not active" at the same time, the device hangs up.
- WHS2 fails sporadically and can only be operated again after the 230 volt supply has been interrupted
** New Feature
- Use of the HmIP-WHS2 in connection with the HmIP-BWTH wall thermostat
** Improvement
- The time information telegram does not contain a note about the sommer / winter time change.
- If possible, send multicasts only to PARTNER_ALL_WIRED_DEVICES instead of to PARTNER_ALL_DEVICES.
Version HmIP-WHS2 V1.4.002 - 2021-11-08
** Bugfix
- CSC werden mit NAK beantwortet.
- NAK auf DEC Execution_Code: Set_weekprogram_target_channel_lock
Version HmIP-WHS2 V1.4.000 - 2018-11-23
** Bugfix
- Homematic IP actuators trigger, due to the astro function, one hour delayed or prematurely on the day of the time changeover.
** New Feature
- Firmware-Erweiterung erforderlich damit Gerät mit HmIP-FALMOT-C12 gepaired werden kann
- AppSequenceCounter-Ãberwachung auf Bereich ausweiten
** Improvement
- All PowerUp parameters, that are listed in list 3 of the device, must be supported
--- END OF FILE ---