Company: eQ-3, Maiburger Str. 29, 26789 Leer, Germany
Version 1.18.10 2022-10-19
** Bugfix
- The current consumption is too high if the sampling time
is more than 2 s and the battery cover is closed.
Version 1.18.8 2022-10-05
** Bugfix
- Boot flag now get reseted correctly after receiving APP ACK. This also solves
Version 1.18.6 2022-09-12
** New Feature
- Hotfix for high current consumption with open housing.
Version 1.18.4 2022-06-28
** New Feature
- Add parameter CYCLIC_BIDI_INFO_MSG_DISCARD
- enable CYCLIC_BIDI_INFO_MSG_DISCARD parameter for all devices
- default value is 30 (every hour)
Version 1.18.0 - 2022-04-28
** New Feature
- Add pairing support (HmIP-SWDO-PL/HmIP-SWDO-PL-2)
- Add support for HmIP-SWDO-2
Version 1.16.10 - 20190227
** Bugfix
- Fixed a bug that
caused setting of alarmworthy event flag with unidirectional
or cyclic status frames.
** New Feature
- Added new device type for HmIP-SWDO-PL.
Version 1.16.8 - 20180302
** Related Hardware
** Bugfix
- Fixed a bug with receiving answers of conditional switch commands.
- Also had to correct the counting of sequence counters if
they are the same as the sequence counter of the status frame.
Version 1.16.6 - 20180221
** Modifications
- Changed counting of event_counter to new mechanism
(boot:0; other:[1..252]).
- Reworked the mechanism of receiving answers.
Version 1.16.4 - 20180209
** Bugfix
- Added separate keypress counter for window and backup.
- All pending flags are now handled after boot process is
finished. Otherwise it is possible to miss an acknowledgment
frame of a frame at boot.
Version 1.16.2 - 20180207
** Bugfix
- Added first statusinfo to the backup mechanism.
Version 1.16.0 - 201802015
** Bugfix
- Added mechanism to prevent overwriting of a alarmworthy
event with a not alarmworthy one.
- Fast window open and close now also causes a backup.
- Fixed a bug with missing MAC_ACKs after blinking.
** New Feature
- Added new parameter DISABLE_MSG_TO_AC.
- Added alarm-channel and depending functionality for
security solution.
** Comments
- Excluded cyclic bidi statusinfo from backup mechanism.
- 'ifdef'-ed some unnecessary parts for contact sensors
without optical detection.
Version 1.14.1 - 20170803
** Bugfix
- Fixed bug in sleep behaviour.
Version 1.14.0 - 20170315
** Bugfix
- Report link partner problem frame now includes the
address of the link partner
- device turn of rx and go to sleep if status info to shc
was ok but at least one link partner hasn't answered
** Modification
- add separate sequence counter for status infos
** Comments
- relevant changes in HMOS:
- Device is 5 seconds awake after sending a Multicast (AllDevices)
- Communication problems with burst receivers when sending multiple
data packets one after the other
Version 1.12.2 - 20170208
** Comments
- Did a actualisation of the firmware converter.
To be sure to be able to differentiate between the old
and the new update file the version was increased.
Version 1.12.1 - 20160425
** Bugfix
- Fixed a bug with ACKs to config update request frames.
Version 1.12.0 - 20160413
** Comments
- Increased version due to change from SVN to GIT
and to new library version.