C H A N G E L O G
Please note: Only use the firmware file in connection with the current software-version of the CCUx!
Device: HmIP-PSM-PE - Homematic IP Pluggable Switch and Meter (Pin-Earth)
Company: eQ-3, Maiburger Str. 29, 26789 Leer, Germany
Version 1 (2 for pluggable).22.8 - 2022-01-25
** Bugfix
- Incorrect output switching under some unfavourable timing and profile conditions
Version 1 (2 for pluggable).22.6 - 2022-01-24
** Improvement
- Improved calibration of the internal rc oscillator (HmIP-FSM/HmIP-FSM16)
Version 1 (2 for pluggable).22.4 - 2022-01-14
** Bugfix
- Error in emergency shutoff functionality
** Modification
- activate power failure detection for all devices with powermeter, zero crossing switching or bistable relays
Version 1 (2 for pluggable).22.2 - 2021-12-09
** Bugfix
- add separate handling of overcurrent shutoff to ensure that output is switched off
- fixed error in emergency shutoff handling for devices with more than one channel
** Modification
Version 1 (2 for pluggable).22.0 - 2021-10-08
** Bugfix
- The time information telegram does not contain a note about the sommer / winter time change.
- Timeout for first factory reset step is too long
- Device sends RequestConfigUpdate if received a MacAck from a LinkPartner
** New Feature
- Transmitting negative power (only measuring actuators)
- Overcurrent detection and shutoff (HmIP-PSM-2/HmIP-PS-2)
Version 1 (2 for pluggable).20.6 - 2021-10-13
** Bugfix
- Fixed Wrong definition of overload error flag
- Fixed error if current is to big (e.g. 26 A -> if power is to big the power meter chip generates an power overflow, this caused a reset of power and current to 0)
** New Feature
- Overcurrent detection and shutoff for switch actuators with metering (HmIP-PSM/HmIP-BSM/HmIP-FSM/HmIP-FSM16)
Version 1 (2 for pluggable).20.4 - 2021-09-16
** Bugfix
- The daylight saving time information is now taken from time information telegram, if included.
** Modification
- Device sends RequestConfigUpdate if received a MacAck from a LinkPartner
Version 1 (2 for pluggable).20.2 - 2021-08-25
** Bugfix
- Update UART communication lib to fix a bug in power meter communication.
Version 1 (2 for pluggable).20.0 - 2021-07-22
** Bugfix
** New Feature
- Support of HmIP-BSM-I
- Reset of power meter chip if the communication is broken.
Version 1 (2 for pluggable).18.22 - 2021-04-12
** Bugfix
- Device responds on multicast frames without ARR bit
- Device sends Status-Frames with Ack-Flag on SwichCommands without ARR-Flag
Version 1 (2 for pluggable).18.20 - 2021-01-15
** Bugfix
- Fixed a bug that with not removing calibration task.
Version 1 (2 for pluggable).18.18 - 2021-01-06
** Improvement
- Switched to usage of internal OSC with permanent calibraton
from the HFXO due to problems when switching non omic loads.
Version 1 (2 for pluggable).18.16 - 2020-08-03
** Bugfix
- Added missing defines for the new statusinfo module in PS,
thus also in PCBS.
Version 1 (2 for pluggable).18.14 - 2020-07-15/2020-07-10
** Bugfix
- Move some routines for testing the relay to ram functions.
- Device send status continuously and leads CCU and device running into duty cycle
Version 1 (2 for pluggable).18.12 - 2020-06-22
** Bugfix
- After inclusion, device sends bidirectional status telegrams
to the CCU after approx. 120s
--- END OF FILE ---