Version 2.0.010 - 2022-05-23

** Bugfix

Version 2.0.008 - 2022-05-10

** Bugfix

Version 2.0.006 - 2022-04-27

** Bugfix

Version 2.0.004 - 2022-03-31

** Bugfix

Version 2.0.000 - 2022-02-07

** Bugfix

** New Feature

** Improvement

Version 1.8.004 - 2019-01-29

** Bugfix * Level Command at analog output fixed * Behaviour of event counter fixed

** Improvement * Split up event counter for digital input channels in case of conditional switch command

** Modification * Change to Version 1.8.004.

Version 1.8.002 - 2019-01-24

** Bugfix * Long keypress behaviour at digital input channels corrected (last long keypress is sent with arr) * Fixed wrong behaviour of application sequence counter

** Improvement * Sending of config request frames in case of no linkpartner at digital input channels

** Modification * Change to Version 1.8.002.

Version 1.8.000 - 2018-12-19

** Bugfix * Weekprogram under certain circumstances does switch all actuator channels if switched all at the same time

** Improvement * Weekprogram implemented * Pairing with FALMOT * All PowerUp parameters, that are listed in list 3 of the device, must be supported. * Disable MSG to AC parameter implemented * Application Sequence Counter handling adapted * Configuration parameter for pushbutton channel (long presstime, double presstime, repeated long press timeout) added

** Modification * Change to Version 1.8.000.

Version 1.6.004 - 2017-11-23

** Improvement * MIOB behaviour in case of system restart improved. Now sends DEC-Logic to FAL in any case.

** Modification * Change to Version 1.6.004.

Version 1.6.002 - 2017-02-09

** Bugfix * In case of multiple FAL, linked to different acutator channels of the MIOB, in some configurations not all FALs got DEC Logic command (eg. for changeover).

** Modification * Change to Version 1.6.002.

Version 1.6.001 - 2017-02-08

** Bugfix * Fixed Issue: Direct execution command was sent to FAL on wrong Channel. If no Link between Out0 and FAL created, no DEC was sent from MIOB

** Modification * Change to Version 1.6.001.

Version 1.6.000 - 2017-01-30

** Bugfix * Error in heat demand function (VIRT B-Channels of both actuators) fixed.

** Modification * Change to Version 1.6.000.

Version 1.4.000 - 2016-09-20

** Bugfix * Issue with global pump protection function (in conjunction with the FAL) fixed.

** Modification * Change to Version 1.4.000.

Version 1.2.000 - 2016-09-08

** Bugfix

* Fixed issue with powerup ontime and powerup ondelay at actuator channels.
* Fixed issue with event delaytime and event randomtime for statusinfo 
  transmission in case of statuschange at actuator channels.
* Fixed issue with log keypress timer at application startup.

** Modification * Change to Version 1.2.000.

Version 1.0.012 - 2016-08-25

** Bugfix

* Bugfix at internal link between input and output channels (CO-Pilot).

** Modification * Change to Version 1.0.012.

Version 1.0.011 - 2016-07-28

** Bugfix * Double ack at csc and usc fixed. * Application sequence counter error fixed.

** Modification * Change to Version 1.0.011. * Changed Lib to 1.16.1

Version 1.0.010 - 2016-07-28

** Bugfix * Bug with DEC of second relay output fixed

** Modification * Change to Version 1.0.010. * Unconditional switch command added for switching actuator channels

Version 1.0.009 - 2016-07-27

** Bugfix

* Application ACK is now sent in case of set ARR Bit.  
* Logic Combination fixed.
* Powerupactions fixed.
* Edit Parameterlist fixed.

** Modification * Change to Version 1.0.009. * Send Statusinfo subsequent to levelcommand or dec with level on channel for analog output. * Statusinfo is only sent in case of "significant" changes.

Version 1.0.008 - 2016-06-21

** Modification * Change to Version 1.0.008. * Minor changes in pairing routines. * Device Functions IDs adapted.

Version 1.0.007 - 2016-06-15

** Bugfix * Bugfix in SNC Command

** Modification * Change to Version 1.0.007. * Internal Links implemented (eg. Link between C/O input and CO-Pilot Output). * Tactile Switch functionality implemented for digital Inputs (sends Unconditional Switch Command with short (<400 ms) or long (>400 ms every 250 ms) keypress). * Statusinfo implemented.

Version 1.0.006 - 2016-06-01

** Bugfix * Bugfix in pairing routines.

** Modification * Change to Version 1.0.006. * Heatdemand relay functions on Virt B channels implemented. * DEC send to FAL if FAL reset has been detected (sequence counter = 0x01).

Version 1.0.005 - earlier - 2016-05-23

** Bugfix * Bugfix in pairing routines.