Device: HmIP-FWI - Homematic IP Wiegand Interface

Company: eQ-3, Maiburger Str. 29, 26789 Leer, Germany

Version 1.0.014 - 2022-04-28

** Improvement In connection with dnt fingerprint code lock BioAccess PRO: Use of 4-Bit or 8-Bit Mode recommended, 10-Bit Mode must not be used.

Version 1.0.012 - 2021-12-10

** Improvement Device does not communicate code inputs and bell contact actuation via status. If an code or a bell operation was detected during normal operation, this was not reported as a status. With the improvement, program actions via the status message are now also possible in addition to the direct link actions. After a firmware update the learned Wiegand codes are still available. After a FW update, the learned codes were no longer available and the customer has to teach them in again. The implementation was extended so that the codes are still known after a FW update. Time duration for the state update at restart of the central unit. When the control panel is restarted, the user channel authorizations are not known and are therefore initially set to "not authorized". The authorization is only correctly stored again when this has been communicated by the device via the corresponding status message. Means: Up to this point, the central program does not function. To solve this problem, this information is always sent when a status is sent due to a Wiegand code detection.

Version 1.0.006 - 2021-07-21

First Release.