C H A N G E L O G
Please note: Only use the firmware file in connection with the current software-version of the CCUx!
Device: HmIP-ESI - Homematic IP Energy Sensor Interface
Company: eQ-3, Maiburger Str. 29, 26789 Leer, Germany
Version 1.4.0 - 2024-03-08
** Bugfix
- Incorrect error message if IEC protocol not recognized
- SML status word of length 1 byte not taken into account
- no protocol detection of D0-D energy counter with 8-N-1 (LOGAREX)
** Improvement
- Statusword under Obis 96.05.05 is not supported
- fix DZG sign workaround
- Error flashing if device is started without sensor
- add OBIS 36.7.0 for single phase power meter
- add workaround for Pafal EA5: take 'F' as 15 into OBIS C
- Improved error handling for configuration change notification on the device to the AP
- An ES-IEC without a recognized protocol should be reported
Version 1.2.2 - 2023-12-14
** Bugfix
- Power consumption too high with ES-LED and ES-Gas
- error code 1 on cloud inclusion
** Improvement
- increase D0-C handshake timeout for LuG
Version 1.0.6 - 2023-11-02
** New Feature
--- END OF FILE ---