C H A N G E L O G
Please note: Only use the firmware file in connection with the current software-version of the CCUx!
Device: HmIP-BROLL - Homematic IP Shutter Actuator for brand switches
Company: eQ-3, Maiburger Str. 29, 26789 Leer, Germany
Version 1.10.16 - 2023-05-04
** Improvement
- The level values 201 (last value) and 202 (don't care) to a virtual channel shall be directly passed through to the real channel
- Execute function "Enable operation within one end position to manually solve any error" only by a long button press
Version 1.10.8 - 2022-11-15
** Bugfix
- If the device is restarted while overtemperature error the first statusinfo after restart doesn't signalize an error
- A long keypress release leads to longer run time than the previous ones if the driving time is shorter than the long keypress repetition time
- After a long keypress the actor runs longer than the set driving time
- Section of virtual channels remains in "Move up/down reference run" if all three virtual channels are triggered by Direct Execution Command at startup
- A command triggered by weekprogram or internal link is handled by the virtual channels although an error is active
- Wrong evaluation of the event counter with multiple links between sensor and actuator
** Improvement
- The level values 201 (last value) and 202 (don't care) to a virtual channel shall be directly passed through to the real channel
- Changing driving directions with HmIP UP actuators via parameters
- HmIP actuators with default links as button pair, should also have ABORT_EVENT_SENDING_CHANNELS as default in pairs
- The time information telegram does not contain a note about the sommer / winter time change
- Enable operation within one end position to manually solve any error
- Switch from external to internal oscillator
- Relay should remain switched on for 2 seconds when reaching the end position, so that the motor can remove the tension
Version 1.8.20 - 2020-11-05
** Bugfix
- Fix error within production relevant functionality
Version 1.8.16 - 2020-02-06
** Bugfix
- Fix error within production relevant functionality
Version 1.8.14 - 2019-10-25
** Bugfix
- Motors start briefly even if the profile parameter MAX_TIME_FIRST_DIR is set to 0.0 s
- HmIP radio shutter and blind actuators can be made to send DeviceInclusions again by a RetriggerDeviceInclusion Request, although this function was only intended for Wired devices
- If the switch-on and switch-off times in the Easy Profile are set to "Not active" at the same time, the device hangs up
- Shutters and blinds with longer driving times do not reach end position by short movements (very small values for MAX_TIME_FIRST_DIR)
- Device does not send a statusinfo if overtemperature was detected
- Device sends empty statusinfo frames
** Improvement
- Improve switch command functionality by new implementation of local loopback, adding command cancelation and using node sending functionality
- Modify event counter check to meet current specification
- If possible, send multicasts only to PARTNER_ALL_WIRED_DEVICES instead of to PARTNER_ALL_DEVICES
Version 1.6.2 - 2018-08-09
** Bugfix
- negative coordinates are not handled correctly
- incorrect data type order for error status info message
- default profile for long keypresses is useless
- problems with automatic measurement of motor delay time
- missing rf connection leads to stop of local operation at long key presses
- bug in the creation of direct execution command for the weekprogram
- actuators trigger, due to the astro function, one hour delayed or prematurely on the day of the time changeover
** Improvement
- new parameter to disable messages to the AC
- new operation mode for wired devices
- event counter validation expanded to range
- all powerup parameters are supported now
Version 1.4.10 - 2017-11-30
** Bugfix
- device doesn't send switching commands anymore if a link partner wasn't reachable before.
** Improvement
- added parameter ENDPOSITION_AUTO_DETECT to give the user the opportunity
to disable the automatic end position detection if an isolating relay is used.
- added parameter DELAY_COMPENSATION to give the user the opportunity to use motors
with greater delay time between switching the relay and start of motor movement.
Version 1.0.10 - 2017-05-11
** First release
--- END OF FILE ---