C H A N G E L O G
Please note: Only use the firmware file in connection with the current software-version of the CCUx!
Device: HmIP-BDT - Homematic IP
Dimmer mit Phasenabschnittsteuerung für Markenschalterserien
Company: eQ-3, Maiburger Str. 29, 26789 Leer, Germany
Version 2.2.4 - 2023-11-10
** Bugfix
- Fixed error which leads to an boot failure under some special conditions.
Version 2.2.0 - 2023-06-08
** Bugfix
- The ON_MIN_LEVEL parameter is evaluated inconsistently for a DEC and a direct link.
** New Feature
- Add separate LED mode with additional configuration parameters for a better dimming behaviour
Version 2.0.0 - 2022-12-06
** Bugfix
- Wrong evaluation of the event counter with multiple links between sensor and actuator
- In a switching group, only the first channels are switched on
- With the settings "Anzahl der auszulassenden Statusmeldungen = 0" and "Anzahl der auszulassenden,unveränderten Statusmeldungen = 0" the status is not transmitted in 2 to 3 minute intervals
- Device sends answers-frame on a TimeInfo from AC to "any-router"-address
- If the switch-on and switch-off times in the Easy Profile are set to "Not active" at the same time, the device hangs up.
- Rocker switch no longer responds after frequent operation
- System LED signals error (red) if rocker switch is linked to internal channel and 2 or more external channels
- Homematic IP actuators trigger, due to the astro function, one hour delayed or prematurely on the day of the time changeover.
- A TimeInfo frame with ARR-Bit will not be answered
- Wrong behaviour if a link partner is answering late
- Device does a reboot if factory reset is aborted
- device uses OFF_LEVEL of a direct link for direct execution command if level of direct execution is 0
- Wrong order of datatypes in the statusinfo frame
- The Weekprogram astro times doesn't work correctly with negative latitude or longitude
- After an OTAU reboot the inclusion requests are send to address 0x000000 sometimes
** New Feature
- Implement channel parameter for setting the Dimm-Min-Level.
- Switch-off ramp via central programs or automation.
- Rework AppSequenceCounter validation to a counter range check
- Support of HmIPW operation mode
- Support of systems and solutions without a central unit (installer solution)
** Improvement
- Switch from external to internal oscillator
- The time information telegram does not contain a note about the sommer / winter time change.
- HmIP actuators with default links as button pair, should also have ABORT_EVENT_SENDING_CHANNELS as default in pairs.
- If possible, send multicasts only to PARTNER_ALL_WIRED_DEVICES instead of to PARTNER_ALL_DEVICES.
- Changing driving directions with HmIP UP actuators via parameters.
- Modify event counter check to meet current specification
- Improve switch command functionality by new implementation of local loopback, adding command cancelation and using node sending functionality
- All PowerUp parameters, that are listed in list 3 of the device, must be supported.
- Changed default values for Powerup action parameters
Version 1.6.0 - 2017-11-21
** Bugfix
- Homematic IP actuators trigger, due to the astro function, one hour delayed or prematurely on the day of the time changeover.
- A TimeInfo frame with ARR-Bit will not be answered
- Device does a reboot if factory reset is aborted
- device uses OFF_LEVEL of a direct link for direct execution command if level of direct execution is 0
- Wrong order of datatypes in the statusinfo frame
- The Weekprogram astro times doesn't work correctly with negative latitude or longitude
- After an OTAU reboot the inclusion requests are send to address 0x000000 sometimes
** New Feature
- Rework AppSequenceCounter validation to a counter range check
- Support of HmIPW operation mode
- Support of systems and solutions without a central unit (installer solution)
** Improvement
- All PowerUp parameters, that are listed in list 3 of the device, must be supported.
- Changed default values for Powerup action parameters
Version 1.4.8 - 2017-08-01
** Bugfix
-
Implement missing support of the direct execution commands LOCK and UNLOCK
-
After the first time NACK answer, all answers are NACK
-
Device hangs up while installing update V1.2.2
-
Wrong applications sequence number after a long keypress
-
If not included, a long keypress triggers an inclusion request all 250 ms
-
Direct execution commands with speciale value level "old value" is not handled correctly
-
Device sends answers on multicast commandand on commands without arr bit in generally
-
If a sending device (RC etc. ) is connected to more than one virtual channel, only the first channel is switching.
-
Modify power up jump targets to match the power up jump targets of the switch actuators
-
Na answer on a configuration commit frame
--- END OF FILE ---